Low Temperature Unit Cooler Evaporator Air Cooler: Specifically designed for cryogenic environments of -18℃ to -35℃. Thick walled seamless internally threaded copper tubing with high-density aluminum fins provides powerful heat exchange even at low evaporation temperatures. High-power stainless steel heating element + anti-freeze heating cable, preventing ice blockage and drain pipe cracking. Zinc plated sheet metal parts with outdoor powder coating provide double rust protection, withstanding alternating hot and cold temperatures. The fan bearings use low temperature resistant grease, and the motor windings are cold resistant and insulated, ensuring smooth operation during extreme cold starts. Say goodbye to frequent defrosting failures, motor burnout, and casing rust; it's the core support for frozen meat, seafood, and ice cream storage.
Customized Services
| Application For Example | Room Temperature |
| Fruit & Vegetable Constant Temperature | 10°C to 20°C |
| Fruit & Vegetable Freshness | 0°C to 15°C |
| Frozen Meat Storage | -5°C to -18°C |
| Quick Frozen Meat Storage | -30°C to -35°C |
| Tuna Fish | -60°C |
| Cold Chain Transportation | -80°C |
Naming Convention
DD(1)-2.8(2)/15(3)
(1)DD
DL: High temperature
DD: Medium temperature
DJ: Low temperature
(2)2.8: Refrigerating capacity
(3)15: Heat transfer area
Technical Parameter
| DJ Type Ceiling Air Cooler Technical Parameters | |||||||||||||
| 9.0 mm Fin Space:9.0mm | |||||||||||||
| Serial Number | Model | Refrigeration Capacity | Nominal Area | Volume | Inlet/Outlet Tube Of Refrigerant | Fan Parameter | Electric Defrost | ||||||
| Number | Fan Diameter | Voltage | Power | Air Volume | Range | Defrosting Power of Fins | Power of Defrosting Pan | ||||||
| W | ㎡ | L | mm | N | mm | V | W | m³/h | m | W | W | ||
| 1 | DJ-1.7/10 | 1700 | 10 | 2.7 | φ12/φ19 | 2 | 300 | 380/220 | 2×75 | 3126 | 8 | 2400 | 1200 |
| 2 | DJ-2.6/15 | 2625 | 15 | 3.5 | φ12/φ19 | 2 | 350 | 380/220 | 2×129 | 4580 | 8 | 2400 | 1200 |
| 3 | DJ-3.4/20 | 3400 | 20 | 5.8 | φ16/φ22 | 2 | 400 | 380/220 | 2×180 | 6800 | 10 | 2400 | 1200 |
| 4 | DJ-5.1/30 | 5100 | 30 | 7.6 | φ16/φ22 | 2 | 400 | 380/220 | 2×180 | 6800 | 10 | 3000 | 1500 |
| 5 | DJ-6.8/40 | 6800 | 40 | 10.1 | φ19/φ32 | 2 | 500 | 380 | 2×414 | 11000 | 15 | 6000 | 1500 |
| 6 | DJ-8.9/55 | 8900 | 55 | 13.5 | φ19/φ32 | 2 | 500 | 380 | 2×414 | 11000 | 15 | 6000 | 1500 |
| 7 | DJ-11.6/70 | 11600 | 70 | 17.3 | φ25/φ40 | 3 | 500 | 380 | 3×414 | 18000 | 15 | 8000 | 4000 |
| 8 | DJ-14.3/85 | 14300 | 85 | 19.6 | φ25/φ40 | 3 | 500 | 380 | 3×414 | 18000 | 15 | 8000 | 4000 |
| 9 | DJ-17.9/105 | 17900 | 105 | 22.7 | φ25/φ48 | 4 | 500 | 380 | 4×414 | 24000 | 15 | 9600 | 4800 |
| 10 | DJ-19.6/115 | 19600 | 115 | 25.8 | φ25/φ48 | 4 | 500 | 380 | 4×414 | 24000 | 15 | 9600 | 4800 |
| 11 | DJ-23.9/140 | 23900 | 140 | 32.2 | φ25/φ50 | 4 | 500 | 380 | 4×414 | 24000 | 15 | 11000 | 4800 |
| 12 | DJ-28.9/170 | 28900 | 170 | 41.9 | φ28/φ54 | 4 | 550 | 380 | 4×600 | 32000 | 15 | 16800 | 4800 |
| 13 | DJ-35.8/210 | 35800 | 210 | 51.6 | φ28/φ54 | 4 | 600 | 380 | 4×780 | 40000 | 15 | 21600 | 4800 |
| For Application To T Library=-25℃,△t=7℃,the Energy Of R134a Should Be Multiplied By The Correction Factor F, Qor134a=qor22xf. | |||||||||||||
Overall Size

| Standard Air Cooler Size Parameters | ||||||||||||
| Serial Number | Model | Shape size | Position size of the mounting hole |
Drainage to take over the outer diameter |
Space | |||||||
| L | B | H | D | E | E1 | E2 | E3 | F | W | |||
| 1 | DL-2/10 | 670 | 460 | 485 | 360 | 455 | / | / | / | 87 | G1" | 300 |
| 2 | DD-1.2/7 | |||||||||||
| 3 | DL-4.3/20 | 1300 | 460 | 485 | 360 | 1085 | / | / | / | 87 | G1" | 300 |
| 4 | DD-2.8/15 | |||||||||||
| 5 | DJ-1.7/10 | |||||||||||
| 6 | DL-6.2/30 | 1300 | 460 | 485 | 360 | 1085 | / | / | / | 87 | G1" | 300 |
| 7 | DD-3.7/22 | |||||||||||
| 8 | DJ-2.6/15 | |||||||||||
| 9 | DL-8.2/40 | 1380 | 480 | 600 | 360 | 1085 | / | / | / | 107 | G1" | 350 |
| 10 | DD-5.3/30 | |||||||||||
| 11 | DJ-3.4/20 | |||||||||||
| 12 | DL-12.3/60 | 1750 | 480 | 600 | 360 | 1455 | / | / | / | 107 | G1" | 350 |
| 13 | DD-7.0/40 | |||||||||||
| 14 | DJ-5.1/30 | |||||||||||
| 15 | DL-16.4/80 | 1920 | 580 | 670 | 470 | 1625 | 800 | / | / | 107 | G1" | 400 |
| 16 | DD-11.2/60 | |||||||||||
| 17 | DJ-6.8/40 | |||||||||||
| 18 | DL-21.5/105 | 1920 | 580 | 710 | 470 | 1625 | 800 | / | / | 107 | G1" | 450 |
| 19 | DD-14.9/80 | |||||||||||
| 20 | DJ-8.9/55 | |||||||||||
| 21 | DL-2.8/125 | 2420 | 580 | 710 | 470 | 2025 | 665 | 665 | / | 107 | G1" | 450 |
| 22 | DD-18.7/100 | |||||||||||
| 23 | D1-I1.6/70 | |||||||||||
| 24 | DL-32.8/160 | 2720 | 580 | 710 | 470 | 2425 | 800 | 800 | / | 107 | G1" | 500 |
| 25 | DD-22.3/120 | |||||||||||
| 26 | DJ-14.3/85 | |||||||||||
| 27 | DL-37.9/185 | 3120 | 580 | 710 | 470 | 2825 | 700 | 700 | 700 | 107 | G2" | 500 |
| 28 | DD-26.2/140 | |||||||||||
| 29 | DJ-17.9/105 | |||||||||||
| 30 | DL-42.9/210 | 3520 | 580 | 710 | 470 | 3225 | 800 | 800 | 800 | 107 | G2" | 500 |
| 31 | DD-29.8/160 | |||||||||||
| 32 | DJ-19.6/115 | |||||||||||
| 33 | DL-53.3/260 | 3520 | 630 | 770 | 520 | 3225 | 800 | 800 | 800 | 107 | G2" | 500 |
| 34 | DD-37.2/200 | |||||||||||
| 35 | DJ-23.9/140 | |||||||||||
| 36 | DL-69.4/340 | 3520 | 680 | 940 | 570 | 3225 | 800 | 800 | 800 | 107 | G2" | 610 |
| 37 | DD-48.4/255 | |||||||||||
| 38 | DJ-28.9/170 | |||||||||||
| 39 | DL-83.6/410 | 3520 | 680 | 1140 | 570 | 3225 | 800 | 800 | 800 | 107 | G2" | 610 |
| 40 | DD-57.9/310 | |||||||||||
| 41 | DJ-35.8/210 | |||||||||||
Packaging


Hot Tags: unit cooler evaporator, China unit cooler evaporator manufacturers, suppliers, factory, Refrigeration Evaporator, cold room evaporator unit, Cooler Evaporator, air cooled evaporator, air evaporator, evap cooler